- To improve search results for Aspen Hysys 7.3 try to exclude using words such as: serial, code, keygen, hacked, patch, warez, etc. Simplifying your search query should return more download results. Many downloads like Aspen Hysys 7.3 may also include a crack, serial number, unlock code or keygen (key generator).
- The steps to set up this simulation in previous versions of HYSYS (back to v8.6) are essentially the same, though some of the screen options may be slightly different. Create new simulation file When running under Windows 10 you can start the program from Start, the all programs list, Aspen HYSYS, Aspen HYSYS V10.
- How to install it? 1) either follow the instruction in the text file inside (named READ ME! 2) or see this video:).
Aspen hysys free download - Aspen Strong, Aspen Dental, Aspen Spora, and many more programs. AspenTech aspenONE 9.1 AspenTech aspenONE product of Aspen. The collection includes several software is the most common and widely used of Aspen HYSYS.
Aspentech’s Hysys is a process simulation tool. You always have to pick a “fluid package” when you use the program: a thermodynamic method it will use to calculate properties, especially vapour-liquid equilibria. I watched an old “webinar” (presentation given through the Internet) on their property packages and took some notes.
You can combine this post with the Hysys manual, the Hysys property package wizard, Aspentech Support’s advice, and books on simulation, and put it all together to choose the best package in each case. If you are in doubt Aspentech Support can always give you personalized advice. They are really quite good at quickly suggesting the best method to use.
One trick to remember is that you can use different fluid packages and different component lists in different parts of the simulation. You can have a Peng-Robinson Package running the calculations for your hydrocarbons, and the ASME Steam Package running the steam and water calculations.
Here are my notes from the webinar:
-Hydrocarbons: normally use an Equation of State method
-Vapour pressure models are OK at low pressures
-Activity coefficient like NRTL is poor model for hydrocarbons
-Vapour pressure models are OK at low pressures
-Activity coefficient like NRTL is poor model for hydrocarbons
Equations of State:
-Peng-Robinson is most enhanced in Hysys, highest T & P range, has special treatment for key components, largest binary interaction database: good standard for hydrocarbons
-PRSV: extends PR to moderately non-ideal systems and better represents poor components and mixtures. Adds a new parameter to the equation. Slower calculation speeds than Peng-Robinson
-SRK: modified Redlich Kwong model. Similar accuracy/use as Peng Rob, but in Hysys SRK has less enhancements than PR.
-PR-Twu, SR-Twu for hydrogen solutes? In liquid hydrocarbons
-TST: hydrocarbons with non-ideal components (used in glycol package)
-GCEOS: generalized cubic EOS for user to add their own parameters. Use this to build your own model when necessary
-MBWR: a modification of the old BWR models: 32 parameters, more empirical approach, so it works very well in the range where it has data
-Lee-Kesler-Pockler: modified BWR for non-polar substances, mixtures
-BWRS: modified BWR for multicomponents, requires experimental data
-Zudkevitch Joffee: modified RK method for VLE, systems with H2
-Kabadi-Danner: modified SRK with Liquid-Liquid-Equilibrium calcs for liquid H2O-Hydrocarbon systems, especially dilute, parameters must be tuned to experimental data
-Sour PR/SRK: sour water systems with H2S, CO2, NH3 at low to moderate P
-Peng-Robinson is most enhanced in Hysys, highest T & P range, has special treatment for key components, largest binary interaction database: good standard for hydrocarbons
-PRSV: extends PR to moderately non-ideal systems and better represents poor components and mixtures. Adds a new parameter to the equation. Slower calculation speeds than Peng-Robinson
-SRK: modified Redlich Kwong model. Similar accuracy/use as Peng Rob, but in Hysys SRK has less enhancements than PR.
-PR-Twu, SR-Twu for hydrogen solutes? In liquid hydrocarbons
-TST: hydrocarbons with non-ideal components (used in glycol package)
-GCEOS: generalized cubic EOS for user to add their own parameters. Use this to build your own model when necessary
-MBWR: a modification of the old BWR models: 32 parameters, more empirical approach, so it works very well in the range where it has data
-Lee-Kesler-Pockler: modified BWR for non-polar substances, mixtures
-BWRS: modified BWR for multicomponents, requires experimental data
-Zudkevitch Joffee: modified RK method for VLE, systems with H2
-Kabadi-Danner: modified SRK with Liquid-Liquid-Equilibrium calcs for liquid H2O-Hydrocarbon systems, especially dilute, parameters must be tuned to experimental data
-Sour PR/SRK: sour water systems with H2S, CO2, NH3 at low to moderate P
Vapour Pressure Models:
These models OK for hydrocarbons. Historically they were used since computationally they are easier. Now with modern computers EOS models are easy to run, so vapour pressure models are used less often. However, Braun K10 is still good for vacuum units.
-Modified Antonie: OK for low pressure ideal systems
-Braun K10 Model: strictly applicable to only heavy Hydrocarbons @ low pressures
-Esso K: only heavy Hydrocarbons @ low Press
-Modified Antonie: OK for low pressure ideal systems
-Braun K10 Model: strictly applicable to only heavy Hydrocarbons @ low pressures
-Esso K: only heavy Hydrocarbons @ low Press
Semi-Empirical methods:
-Chao-Seader: hydrocarbons if T = 0-500C, P<10,000 kPa
-Grayson-Streed: Chao-Seader extention with emphasis on hydrogen, good if heavy hydrocarbon with lots of hydrogen like hydrotreaters. Is recommended for vacuum units.
-Chao-Seader: hydrocarbons if T = 0-500C, P<10,000 kPa
-Grayson-Streed: Chao-Seader extention with emphasis on hydrogen, good if heavy hydrocarbon with lots of hydrogen like hydrotreaters. Is recommended for vacuum units.
Hysys For Mac Air
-Glycol Package: TEG circulation rates, purities of lean TEG, dew points and water content of gas stream used in natural gas dehydration. Use PR for MEG, DEG, but be careful of results outside of standard range
-Clean Fuels: Thiols and Hydrocarbon
-OLI: electrolyte
-Amine: sour sweetening with amines
-Steam tables: ASME, NBS
-Clean Fuels: Thiols and Hydrocarbon
-OLI: electrolyte
-Amine: sour sweetening with amines
-Steam tables: ASME, NBS
Binary Interaction Permaters:
-Are many defaults, others estimated by BP & Density, most user can overwrite
-Are many defaults, others estimated by BP & Density, most user can overwrite
Hysys For Mac Shortcut
Refining:
-For hydrocarbons and hypocomponents use PR, SRK, or other EOS
-Vacuum unit – GS, PR, BK10
-High-hydrogen units like hydrotreaters – GS, PR, PR-Twu, or ZJ
-Sour gas sweetening – Amine
-Sour water – Sour PR/SRK
-Clean fuels for sulphur components & HC
-Utilities with water – use one of the steam tables. Steam tables are only for 100% water systems but are the best choice for these systems
-For hydrocarbons and hypocomponents use PR, SRK, or other EOS
-Vacuum unit – GS, PR, BK10
-High-hydrogen units like hydrotreaters – GS, PR, PR-Twu, or ZJ
-Sour gas sweetening – Amine
-Sour water – Sour PR/SRK
-Clean fuels for sulphur components & HC
-Utilities with water – use one of the steam tables. Steam tables are only for 100% water systems but are the best choice for these systems
Edits:
2010-11-12 – Added note that multiple fluid packages can be run in the same simulation
Related
Related posts:
Software Aspen Hysys 8.8 Bits x32/x86 Stakeholders Category;; Publisher OS Supported All Current Windows Information Webpage Purchase Contact Support Contact Classrooms/Labs Planned for Labs Courses Licensing Status Free, Available to All License Restricted To Where is Media Located? Contacts License Manager?
Aspen hysys free download - Aspen Strong, Aspen Dental, Aspen Spora, and many more programs. AspenTech aspenONE 9.1 AspenTech aspenONE product of Aspen. The collection includes several software is the most common and widely used of Aspen HYSYS.
No ETS Managed LM? No Link to LM Documentation LM Server N/A LM Server Port Requires Dongle? No Licenses Expires? No Expiration Date Available on SCCM? Yes Propose for Packaging No Packaging in Progress No Package Creator SCCM Supersedence No Available on Casper? No Available on Satellite? No Available on Landscape?
No Available on MyApps? No MyApps Access MyApps Notes.
Aspen Technology aspenONE 10.1 6.5 Gb Aspen Technology, Inc., the asset optimization software company, announced the availability of aspenONE Version 10.1 software. AspenTech’s latest Engineering, Manufacturing & Supply Chain and Asset Performance Management software innovations help leading global companies achieve higher levels of safety and reliability by optimizing asset performance.
What’s new in Aspen Technology aspenONE 10.1: New to the aspenONE Engineering suite, Aspen Operator Training enables the seamless deployment of training for operators and engineers with a dynamic simulation lifecycle solution that brings operator training simulation (OTS) online sooner and sustains safety throughout the lifetime of the asset. Aspen Operator Training integrates technology acquired from Inprocess Technology and Consulting Group with the industry-leading dynamic simulator, Aspen HYSYS® Dynamics, offering OTS solutions that are easily maintained and accurately predict plant behavior. This technology has a proven track record with customers – CEPSA reduced start-up time and lowered production of off-spec products and Perstorp saved valuable production days by reducing start-up time after plant revamps.
Total industry savings from operator training simulation are estimated at $15 million USD per project. Costing updates for Aspen Capital Cost Estimator and enhancements in Aspen Exchanger Design & Rating are also available, in addition to the latest ASME design code updates and new version comparison assistant for Aspen Exchanger Design & Rating.
The Aspen Simulation Workbook excel interface is now compatible with both 32-bit and 64-bit computers. The aspenONE Manufacturing and Supply Chain innovations in Version 10.1 software are designed to improve workflows and enhance usability. The latest aspenONE Manufacturing Execution Systems (MES) software enables easier migration from Process Explorer to the web-based aspenONE Process Explorer. The software also enables users throughout the enterprise to access key performance indicators via real-time KPI dashboards that can be easily configured using improved navigation and drag and drop functionality. Also in aspenONE Asset Performance Management Version 10.1 software, Aspen ProMV enables higher fidelity control and greater insights resulting in high performing batch processes that help consistently produce high quality, optimum yields by identifying and managing the most important underlying sources of variability in operations. See What’s New in version 10 and version 10.1: here About Aspen Technology aspenONE.
AspenTech’s product portfolio represents the broadest footprint of process optimization solutions in the market. Our best-in-class products span engineering, manufacturing, and supply chain operations, enabling you to create and maintain sustainable best practices while driving operational excellence. About AspenTech. AspenTech is a leading software supplier for optimizing asset performance. Casio Fx 991es Plus Emulator.
Our products thrive in complex, industrial environments where it is critical to optimize the asset design, operation and maintenance lifecycle. AspenTech uniquely combines decades of process modeling expertise with big data machine-learning. Our purpose-built software platform automates knowledge work and builds sustainable competitive advantage by delivering high returns over the entire asset lifecycle. As a result, companies in capital-intensive industries can maximize uptime and push the limits of performance, running their assets faster, safer, longer and greener. Product: Aspen Technology aspenONE Version: 10.1 Supported Architectures: x64 Website Home Page: Language: english System Requirements: PC Supported Operating Systems: Windows 7even or newer / Server 2008 R2 SP1, 2012 R2, 2016 Size: 6.5 Gb.
I have a problem in product configuration section. First, I have a security section below the license section which you don’t have in this video. Second, I have a Service Configuration section which automatically fill Domain Username with my Computer’s name and i just need to fill the password. When i fill the password and trying to proceed, it says ” Error:”Computer name” ”Username” is not a domain account. Please sign in to the computer with domain account and relaunch the install.
Please help mee ? I am using 64 bit version. Thank you very much for your help. I have successfully installed ASPEN 8.8 in my Computer and it work perfectly.
But, about 1 week ago, a problem occurred when my nephew changed my computer’s time to! Since that, my aspen can no longer working because license problem: “Unable to Acquire License” with Error Code 26 which is Computer time inconsistency error.
I had uninstalled and try to install it again but the problem still persist. Now i don’t know what to do.
And i think i will keep the program uninstalled until i find the solution. I hope you can help me:'(. Dear HDDE you have to uninstall the software using the given instruction in the video uploaded to youtube channel, and off course you have to search in your windows registry for aspen and remove all the string. For doing that follow this instruction. Use (WIN KEY + R) for run window and type (REGEDIT) and approve the authorization for access to the system settings, and use the (Ctrl + F) for search window and key in (aspen) and also use F3 key to find more. Each time that you found the string you have to delete it completely.
That will solve your problem. After 1 month I’ve used the software with no issue, but recently the license file could not be located. In the error log showed there is two server: Local license sever (No-Net) and my pc server. Description: The license for this product or feature could not be found.
Be sure you are pointing to the correct license file or the license server is configured properly. Do help out in this matter. I’ve tried to uninstall completely based on the tutorial and reinstall it, yet the problem didn’t solve. I also understand that having two servers is kind of weird. Any help will be very grateful. First of all, I really like to appreciate your work and your humble and very Helping attitude for each response.
I recently successfully installed Aspen 8.8 on my friend’s Laptop.While installing it on my own laptop, I am getting an error while running the “wlmadmin” as administrator and clicking on the “sub-nets servers” tab. It says “Sentinel RMS Development Kit: Error[5]: Cannot talk to the license server on host “209.34.83.73:443″, Server not running??” I have also checked the services in MS Configuration but could not find the Sentinel RMS License Manager service. And I also checked the option of “ublock Firewall.bla bla” while installing Sentinel kit.
Hi Energy, First of all I would like to thank you for your seamless support and knowledge. Actually yesterday I just installed Aspen V 8.8 in my windows 10 Laptop. As per your installation note, 737 licenses are found. Then I installed Aspen Exchanger design & Rating module selectively and I is installed successfully with out making any issues. But once I run Aspen EDR model, it is saying license not available for Plate HEX & Shell tube HEX. During this period(from License installation & Model simulation) my laptop was in Air plane mode.
Please help me out in this regard. Thanks in Advance. Hi, I have tried to install Aspen 8.4 on my Windows 10 pro 32 bit machine. The installation completed with out any problem ( I followed your youtube instruction) and activation was successful. But my problem is when ever I start Aspen hysys, a popup message comes and it indicated enterprise database not found.
I have tried both SQL 2012 and 2014. What can be the possible reason? In mixed mode authentication of SQL server what password to be used? Is it should be my laptop admin account password of something else?
Kindly help me to solve the problem. Sorry for any misunderstandings but i am still trying to learn the programm.So the steps from the tutorial that has been given to me goes as follows:Aspen Tech >Aspen Process Modeling >Aspen Properties >Database Manager>“Create a New Database” and then after entering a given password,i should be able to imort an.inp extension file wich contains the physical and chemical properties of a new component.As stated before whenever i try “create new data base” i get the message. Thank you for your efforts. Actually Aspen is new for me, but I found another licens problem witch is directly in Aspenplus. If i have a simple process and activat the economic button and click on “evaluate”, then i get the error massage “Please check your Aspen SLM License and try again”. After this some Capital Cost appear in the green box, but also a yellow triangle apper in the right corner of the green box.
![Hysys for mac os Hysys for mac os](/uploads/1/1/9/5/119565546/662111936.png)
Do you know what is happend or what kind of probemes i could obtain thereby. Thank you for a response. Hi, thanks for your help Now there is another mistake, i simiulate a crystallizer and than i get this massage(see below) in the control panel.
After search in the internet, i thoght i have to install microsoft visual and intel fortran compiler package. But the problem still alive. Do I have to set some special settings anywere or what can i do? Ferdinand ” SEVERE ERROR ERROR COMPILING IN-LINE FORTRAN COMPILER MESSAGES FOLLOW ASPCOMP: Warning! Intel Fortran compiler ifort.exe not found in%PATH% ASPCOMP: Warning! Microsoft C runtime library msvcrt.lib not found in%LIB% ASPCOMP: Warning! Microsoft C runtime library is needed for Dynamic Linking.
ASPCOMP: Warning! Intel Fortran runtime library libifcoremd.lib not found in% ASPCOMP: Warning! Intel Fortran runtime library is needed for Dynamic Linking.
Ifort.exe /nologo /c -DAWINNTN -DWIN32 -I. “-If: programme Aspen (x86) APrS “ •. Dear Moji First of all i want to say thank you for your website and tutorial.i have already installed aspen hysys 8.8 and its working for about a month. Then i change my computer date for some reason and i get this error: Unable to Acquire License (Error Code 26) which is Computer time inconsistency error.
I have already tried uninstall and install the software, following your guide on youtube about how to remove aspen, and deleting all regedit. But its still not working and i still get the same message “Unable to Acquire License” (Error Code 26) Computer time inconsistency error. Please i really need your help about this Best Regards, Phil. Dear Mr Moji, Thank you very much for all of your help and time! I installed Aspen Plus then later i need to install Intel Fortran with Microsoft Visual studio as a linker. Now i have problems with initial steps that how should we configure Aspen Plus For Compiler.
There is Compiler.cfg file provided which we can edit to set up any combination of Compiler and linker and then it sets environment variables (Include, Lib, Path and Use_compaq_Fortran). But unfortunately i don’t have any idea how to do that. Here is an example of Compiler.cfg file which we can modify. Begin Intel_VS9 “Intel Fortran 9.x and Microsoft Visual Studio 2008” IFDir=HKEY_LOCAL_MACHINE(“SOFTWARE Intel Compilers Fortran 9# IA32 ProductDir”) VSDir=HKEY_LOCAL_MACHINE(“SOFTWARE Microsoft VisualStudio 9.0 InstallDir”).. SDKDir=HKEY_LOCAL_MACHINE(“SOFTWARE Microsoft Microsoft SDKs Windows CurrentInstallFolder”) INCLUDE=$(IFDir) Include;$(VSDir) vc atlmfc include;$(VSDir) vc include;$(SDKDir) include LIB=$(IFDir) lib;$(VSDir) vc atlmfc lib;$(VSDir) vc lib;$(SDKDir) lib PATH=$(IFDir) bin;$(VSDir) Common7 IDE;$(VSDir) vc bin;$(VSDir) Common7 Tools;$(SDKDir) bin;$(PATH) USE_COMPAQ_FORTRAN= IFDir= VSDir= SDKDir= End My question is what should be changed here. I use Intel Visual Fortran 16.0 and Microsoft Visual studio 2015. I will be very thankful if you could please help in this regard.
Thank You and Have a Nice Day! Dear mr moji I ınstalled to your video but thıs program say failed.Do you think how can I fix this error: Failed to initialize the Aspen Properties Enterprise Database. Using the configuration file from C: ProgramData AspenTech APED V8.8 ILHAN config.aem The following errors occurred:..APEOSV88: Failed to open the database: The system cannot find the file specified..APV88: Failed to open the database: The system cannot find the file specified..FACTV88: Failed to open the database: The system cannot find the file specified..NISTV88: Failed to open the database: The system cannot find the file specified Please use Database Tester to diagnose and fix the problem. First of all, thanks for taking the time to upload such valuable program. I tightly followed the steps on the video, however I am having an issue. When i run ASPEN HYSIS v8.8 on windows 10(64 bits) this message pops up: “Unable to start Aspen hysis There was a problem getting the license: SLM_HYSYS_Process”. When i click on details it says this: “The license for this product or feature could not be found.
Be sure you are pointing to the correct license file or the license server is configured correctly”. I am not sure if this is the origin of the problem, but when copying the dlll file to the Hyprotech folder the files “world” and “world2” do not have the golden icons showed in the video, instead they show:” DAT archive”.
Help, please and Thanks in advance. I tried to install aspen plus and hysys v8.8 on windows 10, 64 bit operating system. I did everything step by step. All programs are installed succesfully but when I attempt to start hysys, it returned an error saying that: Error Message 1 “None of specified APED databases are accessible.
Hence You can not use Aspen Properties Enterprise Database. ” Error Message 2 “To use Aspen Properties in Hysys, at least one databank should be installed and registered through Aspen Properties Database configuration tool. ” Error Message 3 “Internal error: no such UOM “. Dear Moji, I have formatted my PC and loaded windows 10, 64 bit operating system from scratch and tried ur suggestions. I used SQLSERVEREXP u suggested above this page, exactly the same one ur PC preparation video. I used original name MSSQLSERVER while installing it. I did once again everything step by step as u explained ur video.
Installation of Aspen V8.8 was successful. After installation I have restarted PC and run hyssys as administrator, but I have still the same errors. Error Message 1 “None of specified APED databases are accessible. Hence You can not use Aspen Properties Enterprise Database. ” Error Message 2 “To use Aspen Properties in Hysys, at least one databank should be installed and registered through Aspen Properties Database configuration tool. ” Error Message 3 “Internal error: no such UOM “ Please tell me what else I can do. What’s the problem.
Im about to lose my mind. Hey Thanks for uploading the program. It really helps my study at my university right now. I have some problem with the program. Abt 2 months ago until yesterday the program works just perfectly fine.
But yesterday I accidently change the date of my PC. The Hysys then has “There was a problem in getting the license: SLM_HYSYS_Process.” error. These are the result of the error ————– SLM Common Error Dialog ————— Application: AspenHysys.exe ————— Information Flags ————— Error while checking out license HYSYS_Process ————— Sequence of Events ————— Server: Local license server (NO-NET) Bucket: default Type: Unified License Code: 18 Description: The license for this product or feature could not be found. Be sure you are pointing to the correct license file or the license server is configured properly Server: Local license server (NO-NET) Bucket: default Type: Token License Code: 18 Description: The license for this product or feature could not be found. Be sure you are pointing to the correct license file or the license server is configured properly Server: Local license server (NO-NET) Bucket: default Type: Standard License Code: 18 Description: The license for this product or feature could not be found. Be sure you are pointing to the correct license file or the license server is configured properly Server: GP1101 Bucket: default Type: Unified License Code: 26 Description: This license is currently disabled due to an inconsistency in the computer’s system clock. Please contact AspenTech to correct this problem Server: GP1101 Bucket: default Type: Token License Code: 18 Description: The license for this product or feature could not be found.
Be sure you are pointing to the correct license file or the license server is configured properly Server: GP1101 Bucket: default Type: Standard License Code: 18 Description: The license for this product or feature could not be found. Be sure you are pointing to the correct license file or the license server is configured properly I even already uninstall all of the programs (ASPEN 8.8 and Sentinel License Manager) but the error still come.
How do I fix the problem? Any help will be very appreciated. Thank You so MUCH! I want to thank you for all the technical support you’ve been offering Aspen users in this platform.
![Hysys for mac installer Hysys for mac installer](/uploads/1/1/9/5/119565546/945490550.jpg)
I use to have Aspen 8.6 which was working fine in my windows 10 64bit, but at a point i had issues with the license, i can’t remember what exactly the problem was, but i just couldn’t use Aspen 8.6 anymore. But recently i downloaded the Aspen 8.8 from the link you gave and firstly i had to uninstall the previous version 8.6 by following this link you gave:.
Hysys For Mac Software
Later i had to follow the installation procedure you for the new version 8.8 via this link:. But here is the problem, after setting my rules in the environment variable and disconnecting my internet without disabling the network adapter, i ensured i ran Wlmadmin as an administrator but i could not find my PC name under the subnet servers rather what i see is clients2.google.com. Please what options do i have? Thanks in anticipation for your reply. Dear Moji Thanks for your reply and am sorry for not coming back to this forum to state how I finally resolved it on my own “NOT FINDING PC NAME DISPLAYED IN SUBNET SERVER”. Well I could remember trying to use clients2.google.com which was displaying instead of my PC NAME but to no avail. The solution to it was that i realize when left my internet on and run Wlmadmin as an administrator, my PC NAME displayed, immediately i saw my PC NAME which i indicated in the environment variable, i disconnected the internet immediately, then selected the PC name which then ran the licence, and everything went perfect.
In a nut-shell leaving your internet on while u run Wlmadmin and disconnecting the internet after ur PC name displays fixes the licence problem. Dear Moji, Thank you for the video you uploaded on youtube on how to install ASPEN ONE V8.8. It is highly educative and helpful. I followed your step by step instructions as per the video and was successfully installed ASPEN ONE and ASPEN HYSYS to my system this morning,(around 1 to 2am). I am highly grateful. During the installation, I had problem in attaching license text file by running wlmadmin as an administrator. At first, it was showing not responding so I closed the window after some time and then try to do it again.
When I tried the second time, an error message popped up and said the license file already attached and when I tried to close the window, another message popped up again saying the file could not be attached and the error message continued from attached window to not attached window and could not allowed me do anything. So I then restart my system and then proceed to installation which was very successful.
After installation and trying to run HYSYS as an administrator, a message popped up saying all licenses are currently in use. I then visited your site energygroup.ir and then downloaded the dll file from there. I then copy it to the directory as per the instruction of your youtube video but the problem still persists. I saw a similar problem in the comment section in your site and your advice which I quickly followed.
I deleted the variable through the environmental variable and then restart my system but going through the wlmadmin procedure again, I noticed that the system was able to detect my system name through the subnet even when I had already deleted the variable rule earlier and the problem still persists. I can’t use the aspen hysys or aspen plus. Please help me out. I really need it for my project. I attach here a screenshot of the error message. My system configuration: Intel core i7, 64bit, 8gb ram. Looking forward to your respond soon.
Kind regards, Aliyu.